3150 kVA Transformer A cikin Tsarin Wuta-0.4 / 6.6 kV|Afirka ta Kudu 2025

3150 kVA Transformer A cikin Tsarin Wuta-0.4 / 6.6 kV|Afirka ta Kudu 2025

Ƙasa: Afirka ta Kudu 2025
Yawan aiki: 3150 kVA
Wutar lantarki: 0.4/6.6 kV
Feature: Hot galvanized
Aika Aikace-aikacen

 

 

3150 kVA transformer in power system

Haɗa makoma tare da Stable Current, Zaɓi Canjin Rarraba don Tsangwama Sifili!

 

01 Gabaɗaya

1.1 Fagen Aikin

3150 kVA step up man immersed rarraba transfoma aka isar zuwa Afirka ta Kudu a 2025. Ƙididdiga ikon na transformer ne 3150 kVA tare da ONAN sanyaya. Babban ƙarfin lantarki shine 0.4 kV, ƙarfin lantarki na biyu shine 6.6 kV tare da ± 2 * 2.5% tapping range (NLTC), sun kafa ƙungiyar vector na Dyn11.

Wannan na'ura mai rarrabawa 3150kVA an yi niyya da farko don amfani da tsarin samar da wutar lantarki don ingantaccen juyi da rarraba wutar lantarki. Dukansu manyan ɓangarorin wutar lantarki{2} da ƙananan - an sanye su da akwatunan kebul na keɓe don amintaccen haɗin kebul da kiyayewa. An sanye shi da iskar gas mai mahimmanci wanda ke lura da yanayin iskar gas na cikin gidan transfoma a ainihin lokacin, yana gano kuskuren ciki da gazawar rufewa. A cikin yanayin samar da iskar gas mara kyau, iskar gas zai yi aiki da sauri don yanke wutar lantarki, tare da hana haɓakar hatsarori. An shigar da madaidaicin ma'aunin zafi da sanyio - don saka idanu akan yawan zafin jiki da kuma tabbatar da aiki a cikin kewayon zafin jiki mai aminci. Ana ba da ma'aunin zafin jiki na mai don saka idanu da zafin jiki na mai canzawa, yana tabbatar da kyakkyawan aikin watsar da zafi da kuma tasirin rufewa.

 

 

1.2 Ƙayyadaddun Fasaha

3150 kVA mataki sama mai immersed rarraba tasfo bayani dalla-dalla da bayanai takardar

Isarwa zuwa
Afirka ta Kudu
Shekara
2025
Nau'in
Mai nitsewa rarraba wutar lantarki
Daidaitawa
Saukewa: IEEC60076
Ƙarfin Ƙarfi
3150 kVA
Yawanci
50HZ
Mataki
Single
Nau'in Sanyi
ONAN
Babban Voltage
0.4 kV
Na biyu Voltage
6.6 kv
Abubuwan Iska
Aluminum
Impedance
5.92%
Matsa Canji
Farashin NLTC
Taɓa Range
±2*2.5%
Babu Asara Load
2.94 kW
Akan Rasa Load
32.8 kW
Na'urorin haɗi
Daidaitaccen Kanfigareshan
Jawabi
N/A

 

1.3 Zane

3150 kVA mataki sama mai immersed mai rarraba wutar lantarki girma da nauyi cikakken bayani

3150 kVA step up oil immersed distribution transformer drawing 3150 kVA step up oil immersed distribution transformer nameplate

 

 

02 Masana'antu

2.1 Kori

Ƙirar ainihin ƙafar ƙafa uku{0}sashi na uku{1} yana haɓaka da'irar maganadisu, haɓaka amfani da motsin maganadisu. A sakamakon haka, na'urar ta atomatik na iya ɗaukar matakan wutar lantarki mafi girma tare da ƙaramin girma da nauyi, yana nuna babban ƙarfin ƙarfin. Amfani da manyan-kayan aiki da ingantattun hanyoyin kera yana rage girman asara da rashin jin daɗi a halin yanzu, yana haɓaka ƙarfin ƙarfin injin na'ura a ƙarƙashin yanayin lodi, wanda yayi dai-dai da makamashin zamani-ceto da buƙatun kare muhalli.

three-phase three-leg core design

 

2.2 Guda

3150 kVA step up oil immersed distribution transformer foil winding

Ƙarƙashin wutar lantarki yawanci yana ɗaukar ƙira ta foil, ta amfani da sirara da faɗin tagulla ko foils na aluminum don samar da hanyoyin madugu iri ɗaya. Wannan ƙira ba kawai yana haɓaka ƙarfin injin gabaɗaya ba amma har ma yana rage juriya na iska. Babban wutar lantarki shine waya -rauni kuma siririyar waya tare da magani na musamman na iya jure babban ƙarfin lantarki ba tare da lalacewa ba, yana tabbatar da aminci da kwanciyar hankali na aikin na'urar.

 

2.3 Tanko

An lulluɓe tankin da lalata ta musamman -mai jurewa da UV{1}} Layer mai juriya don biyan takamaiman buƙatun muhallin samar da wutar lantarki, yana tabbatar da tsayayyen aiki na tsawon lokaci. Ƙirar tana bin aji na kariya IP44 da sama, yadda ya kamata yana hana ƙura da shigar danshi, kiyaye amincin kayan aiki a ƙarƙashin yanayin waje.

3150 kVA step up oil immersed distribution transformer oil tank

 

2.4 Taron Karshe

3150 kVA step up oil immersed distribution transformer  assembly

Babban Taro: A kiyaye harhada ainihin kan firam ɗin tushe, tabbatar da amincin da'irar maganadisu.

Shigar da iska: Shigar da ƙananan ƙarfin lantarki da ƙananan ƙarfin wutar lantarki a jere, tabbatar da kariya da keɓewa.

Kanfigareshan Tsarin Sanyaya: Shigar da tsarin sanyaya (tankin mai da radiators) da kuma cika shi da man fetur don taimakawa wajen zubar da zafi.

Haɗin Kayan Wutar Lantarki: Haɗa kwamiti mai kulawa, relays, da masu sauyawa, tabbatar da ingantaccen magani.

Kundin taro: Shigar da kwandon kariya, saduwa da bukatun aji na kariya na IP don hana ƙura da shigar ruwa.

 

 

03 Gwaji

1. Ma'aunin Juriya na Insulation

2. Bincika Matsayin Voltage da Ƙungiyar Vector

3. Ma'aunin Juriya na iska

4. Rarrabe -Ikon Tushen{2}} Gwajin Jure Juyin Wutar Lantarki

5. Gwajin Juriya da Ƙarfin Wutar Lantarki

6. Auna A'a -Asar lodi da A'a - lodin Yanzu

7. Ma'auni na Impedance Voltage da Load asarar

 

3150 kVA step up oil immersed distribution transformer  test
3150 kVA step up oil immersed distribution transformer  testing

 

04 Yanar Gizo da Takaitawa

Mun gode da koyo game da Rarraba Transformer. Mun himmatu wajen samar wa abokan ciniki ingantattun hanyoyin samar da wutar lantarki mai inganci, aminci, kuma abin dogaro don taimaka muku haɓaka rarraba wutar lantarki da rage yawan kuzari. Ko kuna cikin ababen more rayuwa na birane, samar da masana'antu, ko gine-ginen kasuwanci, na'urorin canjin mu na iya biyan bukatun ku da tabbatar da ingantaccen wutar lantarki. Don ƙarin bayani ko tambayoyi, da fatan za a ji daɗi don tuntuɓar ƙungiyar kwararrun mu. Muna sa ran yin aiki tare da ku don inganta ci gaba mai dorewa!