2400 KVA Residential Underground Transformer-13.2/0.6 KV|Amurka 2026

2400 KVA Residential Underground Transformer-13.2/0.6 KV|Amurka 2026

Ƙasar Bayarwa: Amurka 2025
Yawan aiki: 2400kVA
Wutar lantarki: 13.2/0.6kV
Siffar: 99.29% DOE
Aika Aikace-aikacen

Jiangshan Scotech Electric Co., Ltd yana ɗaya daga cikin amintattun masana'anta kuma masu samar da taswirar gida na 2400 kva{6}}13.2/0.6 kv|Amurka 2026 in China. Da fatan za a ji kyauta don siyan kayayyaki masu inganci don siyarwa anan kuma ku sami zane-zane daga masana'anta. Tuntube mu don ƙarin bayani.

 

image003

 

 

01 Gabaɗaya

1.1 Bayanin Aikin

A cikin Afrilu 2026, wani ɗan kwangilar kayan aiki na Amurka ya ba da umarnin injin taswirar ƙasa mai nauyin 2400 kVA don aikin rarraba mazaunin ƙarƙashin ƙasa. An ƙera tafsirin don 13.2kV ​​mai tushe-wye firamare irin ƙarfin lantarki da 0.6 kV na biyu tare da daidaitawar ƙungiyar YNyn0, wanda ke aiki azaman babban hanyar haɗin wutar lantarki ta ƙasa don madauki na mazaunin- cibiyoyin rarraba ciyarwa.

Don tallafawa waɗannan buƙatun, an ƙirƙira injin taswirar ƙasa tare da ruwa mai hana ruwa FR3, tsari guda uku -fase biyar{2}}, da kuma 99.29% mai inganci- aiki mai inganci. Ƙarin saiti sun haɗa da masu kama walƙiya, ma'aunin sa ido tare da lambobin ƙararrawa, haɗin akwatin tasha, ƙaramin tsari-gefen wutar lantarki{7}}tsarin fita, da windows dubawa na duka sassan HV da LV don haɓaka ganuwa aiki da amincin kiyayewa.

Har ila yau, taranfomar ta ɗauki madaidaicin madaidaici{0} feed matattu{1}}kushin gaba{2}}tsarin da aka ɗora tare da hadedde tsarin garkuwa na ƙasa, 600 A ɗaya-tsayi mai tsayi{5}}ƙarar wutar lantarki, gefe{6}ya hau 10-rami ƙasan rami-ƙarfin wutar lantarki da farin foda{2} 9003) don wuraren rarraba mazaunin karkashin kasa na waje. Yayin tabbatar da samarwa, abokin ciniki ya kuma nemi ainihin daidaitaccen madaidaicin madaidaicin madaidaicin matsayi guda huɗu{13} don a sake fasalinsa zuwa maɓalli na ɗaukar nauyi mai matsayi biyu dangane da ainihin ayyukan aiki na kayan amfani.

An kera na'urar taswirar da ke ƙarƙashin ƙasa bisa ga IEEE Std C57.12.34{1}}2022 buƙatun tare da daidaitawar farantin suna mai alamar UL don aikace-aikacen amfanin ƙasa na Arewacin Amurka.

 

 

 

1.2 Ƙayyadaddun Fasaha

2400 kVA ƙayyadaddun kayan aikin canji da takaddar bayanai

Isarwa zuwa
Amurka
Shekara
2026
Nau'in
Uku lokaci kushin Dutsen Transformer
Daidaitawa
IEEE Std C57.12.34-2022
Ƙarfin Ƙarfi
2400 KVA
Yawanci
60HZ
Ciyarwa
Madauki
Gaba
Matattu
Mataki
uku
Nau'in Sanyi
KNAN
Liquid insulant
Farashin FR3
Babban Voltage
13.2 kV GrdY / 7.62 kV
Na biyu Voltage
0.6 kV Y / 0.347 kV
Ƙungiyar Vector
YNyn0
Abubuwan Iska
Aluminum
Impedance
5.75%
Nagarta da Asara Daidaitawa
99.29%
Matsa Canji
Farashin NLTC
Taɓa Range
±2*2.5%
X/R
6.3
Babu Asara Load
3.2 kW
Akan Rasa Load
24 kW

 

1.3 Zane

2400 kVA mazaunin karkashin kasa zane da farantin suna

image005 image007

 

 

02 Masana'antu

2.1 Uku -Mataki na Biyar{2}} Ƙafafun Ƙafafu

Na'urar taswira ta zama tana ɗaukar tsari mai tushe guda uku{0}sashi na biyar-wanda aka ƙera don inganta ma'aunin maganadisu, rage hasarar sifili{2}, da haɓaka kwanciyar hankali a ƙarƙashin ƙasa na lodawa. Ƙirar tana goyan bayan ingantaccen aiki mai girma- har zuwa 99.29% kuma yana haɗa kariyar garkuwar ƙasa don ingantacciyar tsarin tsaro a cibiyoyin rarraba ƙasa na zama.

image009
image011

 

2.2 Karancin -Tsarin iska mai asara

Wurin zama na ƙasa yana amfani da iska na aluminium wanda aka ƙera don aikin 13.2 kV / 0.6 kV YNyn0, yana ba da canjin ƙarfin lantarki, ingantaccen aikin zafi, da rage asarar aiki na dogon lokaci{3} aikace-aikacen rarraba wutar lantarki na ƙasa.

image013
image015

 

2.3 Tsarin Tanki & Duban gani

image017

Kunshin da aka hatimi - Tsarin tankin da aka ɗora na gidan wutan lantarki an ƙera shi don FR3 mai sanyaya ruwa kuma yana haɗa ƙanƙanta{2}}aramin ginin tashar wutar lantarki, tsarin garkuwar ƙasa, da tagogin gani na ɗakunan HV da LV. Wannan saitin yana haɓaka ganuwa na aiki, dacewa da kulawa, da aminci gabaɗaya a cikin na'urori masu canjin gidaje na ƙasa.

 

2.4 Kariya & Haɗin Sa ido

Don inganta aikin kariya da saka idanu na aiki, injin da ke cikin ƙasa yana sanye da masu kama walƙiya, na'urar rage matsa lamba, bawul ɗin nitrogen, da na'urorin sa ido tare da abubuwan tuntuɓar, gami da ma'aunin matsa lamba, ma'aunin matakin mai, da ma'aunin zafin jiki. Waɗannan ƙa'idodin suna goyan bayan mai amfani{1}} sa ido akan sa ido da ingantaccen aiki na taswira na ƙasa.

image019

 

2.5 Karancin -Tsarin Fitar Wutar Wuta

Taswirar karkashin kasa ta zama tana ɗaukar ƙaƙƙarfan daidaitawar tashar tashar wutar lantarki tare da keɓaɓɓen akwatin tasha da 10{2}}rami spade{3}}waɗanda ke ba da damar sauye-sauyen hanyar kebul, tsaran filaye, da shigarwa mafi aminci don tsarin rarraba mazaunin ƙasa.

image021
image023

 

 

03 Gwaji

Matsayin Gwaji

image025

image027
image029

Sakamakon Gwaji

image031

image033

 

 

04 Shiryawa da jigilar kaya

image035
image037

 

Hot Tags: 2400 kva mazaunin karkashin kasa tafsiri-13.2 / 0.6 kv|usa 2026, China 2400 kva tasfoma a karkashin kasa na zama-13.2/0.6 kv|usa 2026 masana'antun, masu kaya, masana'anta