Jagora zuwa Haɗin Canzawa na Delta da Wye

May 08, 2026

Bar sako

delta and wye connection

 

 

 

 

1. Gabatarwa

 

 

Tsarukan rarraba wutar lantarki na lokaci uku- sun dogara sosai akan nau'ikan haɗin taswira guda biyu: Delta (Δ) da Wye (Y). Waɗannan ƙayyadaddun ƙayyadaddun ƙayyadaddun ƙayyadaddun ƙayyadaddun ƙayyadaddun ƙayyadaddun ƙayyadaddun ƙayyadaddun wutar lantarki da igiyoyin ruwa suke, yadda za a iya haɗa lodi, da kuma yadda tsarin ke amsa kurakurai da rashin daidaituwa. FahimtaDelta da Wye haɗin gwiwayana da mahimmanci ga injiniyoyin lantarki, masu sarrafa kayan aiki, da ƙwararrun masana waɗanda ke ƙira, aiki, ko kula da tsarin wutar lantarki.

Wannan jagorar ya ƙunshi halaye, fa'idodi, iyakancewa, da aikace-aikace masu amfani na kowane nau'in haɗin gwiwa, tare da mafi yawan gama-garin haɗin kai da ma'aunin zaɓi.

 

 


 

 

 

2. Fahimtar Haɗin Delta da Wye

 

 

 

Wye Connection

2.1 Haɗin Wye

A cikin haɗin Wye (ko Tauraro), ƙarshen kowane ɗayan iskar taswira guda uku yana haɗe zuwa wuri na tsakiya gama gari wanda aka sani da tsaka tsaki. Sauran ƙarshen suna haɗawa da layin lokaci guda uku, suna yin siffa mai kama da harafin "Y". Wannan tsarin yana haifar da tsarin waya guda huɗu-{3}} madugu na lokaci uku tare da madugu tsaka tsaki.

Matsayin tsaka tsaki yana ba da matakan ƙarfin lantarki daban-daban guda biyu: layi -zuwa{1}}layin wutan layi (yawanci mafi girma) da layi{2}}zuwa{3}}ƙaramar wutar lantarki (ƙasa). Misali, tsarin 480Y/277V wye yana samar da 480V tsakanin matakai don kayan aiki na lokaci uku{8} da 277V daga kowane lokaci zuwa tsaka tsaki don ɗaukar nauyi na lokaci ɗaya{10}. An bayyana dangantakar lissafi kamarinfo-243-47, ma'ana wutar lantarkin layin yana kusan sau 1.732 na lokacin ƙarfin lantarki.

Haɗin Wye kuma yana ba da damar ƙaddamar da tsaka-tsakin tsaka-tsakin, wanda ke kafa ƙaƙƙarfan tunani mai ƙarfi kuma yana haifar da ƙaramar hanyar dawowar matsananciyar rashin ƙarfi. Tsakanin tsaka-tsakin na iya zama ƙasa mai ƙarfi, ƙasa ta hanyar resistor, ko hagu yana iyo dangane da buƙatun tsarin. Koyaya, idan tsaka tsaki ya bar ƙasa ko ya katse, haƙurin kuskure yana raguwa sosai kuma saurin ƙarfin lantarki na ba zata na iya lalata kayan aiki.

 

 

2.2 Haɗin Delta

 

Haɗin Delta yana haɗuwa da kowane ƙarshen iska mai juyawa -zuwa{1}}ƙarshe don samar da rufaffiyar madauki mai kusurwa uku. Kowane kusurwa na triangle yana aiki azaman wurin haɗi don layin lokaci ɗaya. Ba kamar tsarin Wye ba, Delta ba ta da ma'ana ta tsaka-tsaki{4}}tsarin waya ce guda uku{{5} tare da masu gudanar da lokaci uku kawai.

Delta Connection

A cikin saitin Delta, wutar lantarkin layin yayi daidai da ƙarfin wutar lantarki a kowane juyi, yayin da ake rarraba layin halin yanzu wanda kowane juzu'i na ɗaukar lokaci yana ɗaukar kusan 58% (info-80-44) na halin yanzu. Ƙirƙirar madauki{1} rufaffiyar tana ba da ƙarfin zagayawa na yanzu da kyakkyawan aiki ƙarƙashin kaya masu nauyi. Ko da ɗaya - naúrar lokaci ɗaya a bankin Delta ta gaza, sauran biyun za su iya ci gaba da isar da wutar lantarki guda uku{4} a kusan kashi 58% na iya aiki na asali{6}} galibi ana kiranta "buɗewa-delta".

Rashin tsaka tsaki yana sauƙaƙa babban -ikon uku- bayarwa na lokaci amma yana sanya iyakancewa: Haɗin Delta ba za su iya samar da kaya ɗaya ba kai tsaye ba tare da ƙarin kayan aiki ba, kuma ƙasa tana buƙatar hanyoyi na musamman saboda babu tsaka-tsakin yanayi.

 

 


 

 

 

3. Maɓalli Maɓalli a Kallo

 

 

Siffar

Delta (Δ)

Waye (Y)

Kanfigareshan

Rufe madauki alwatika

Siffar tauraro tare da tsaka tsaki na tsakiya

Wayoyi

3-tsarin waya (hanyoyi kawai)

4-tsarin waya (+ tsaka tsaki)

Dangantakar wutar lantarki

info-173-43

info-243-47

Batun tsaka tsaki

Babu samuwa

Akwai (za a iya ƙasa)

Ƙarfin lokaci ɗaya{{0}

Ba za a iya ba da kaya guda ɗaya{0} kai tsaye ba

Dual Voltage for single -phase and three-sease

Ragewar masu jituwa

Tarko harmonics sau uku a ciki

Mafi saukin kamuwa (yana buƙatar ragewa)

Haƙuri na kuskure

Ci gaba da buɗewa{0}delta bayan coil ɗaya ta gaza

Ya dogara da daidaitawar ƙasa tsaka tsaki

Aikace-aikace na yau da kullun

Babban watsa wutar lantarki{0}, manyan injinan masana'antu

Tsarin rarrabawa, gauraye{0} amfani da gine-gine, wuraren kasuwanci

 

Teburin ya nuna cewa Delta tana ba da fifiko ga ƙarfi da inganci don nauyi mai nauyi guda uku{0}, yayin da Wye ke ba da juzu'i da ingantaccen ƙasa don tsarin tare da gauraye nau'ikan kaya.

 

 


 

 

 

4. Haɗaɗɗen Tsarin Canji

 

 

Masu canji za su iya haɗa Delta da Wye akan iskar su na farko da na sakandare ta hanyoyi guda huɗu. Nau'in juyi na farko an jera su da farko (gefen H, babba), sannan nau'in juyi na biyu (gefen X, ƙananan haruffa).

 

 

4.1 Delta -Wye (Δ-Y)

 

 

Wannan ita ce haɗin da aka fi amfani da shi na zamani{0}. Na farko shine an saita Delta{2}, yayin da sakandare ke amfani da haɗin Wye, yawanci tare da tsaka tsaki.

Me Yasa Ya Yi Shahanci:Firamare na Delta ya keɓe tsarin sama daga rashin daidaituwa da jituwa. Duk wani tsaka-tsakin igiyoyin ruwa da aka samar ta rashin daidaituwa guda ɗaya - lodin lokaci na biyu yana yawo a cikin iskar Delta maimakon komawa zuwa tushen farko. Wannan yana haifar da tsaftataccen iyaka na lantarki{3}} na sama yana ganin daidaitaccen tsarin waya guda uku{4}, yayin da magudanar ruwa na iya ɗaukar gauraya guda ɗaya{5}}sashe da nau'i uku{6} tare da tsayayyen tsaka tsaki.

Aikace-aikace na yau da kullun:Matsakaicin masu amfani suna sauka da ƙarfin watsawa (13.8 kV, 34.5 kV) zuwa matakan rarraba (208Y/120V, 480Y/277V); gine-ginen kasuwanci da ke buƙatar duka - wutar lantarki na zamani da hasken wutar lantarki 120V; masana'antu shuke-shuke ciyar da sakandare rarraba bangarori; da cibiyoyin bayanai suna buƙatar tsayayyen shiga tsakani don kayan aikin IT. Sakandare na 208Y/120V ya kusan zama a ko'ina a wuraren kasuwanci na Arewacin Amurka.

Amfani:

  • Yana ba da tsaka-tsakin tsaka-tsaki don amintaccen lodawa guda ɗaya{0}
  • Ya keɓance tsarin farko daga haɗin kai na biyu (harmonics uku da aka kama a Delta)
  • Yana ɗaukar nauyin marasa daidaituwa yadda ya kamata ba tare da gagarumin murdiya ba
  • Yana ba da damar ingantaccen mataki{0}} sauƙaƙan canjin wutar lantarki

Iyakoki:Yana gabatar da canjin mataki na digiri 30 tsakanin firamare da na biyu (wanda aka tattauna a ƙasa), wanda dole ne a yi la'akari da shi lokacin da aka haɗa tasfofi. Hakanan, Delta firamare ba za su iya samar da tsaka tsaki ga tsarin sama ba.

Dyn1

4.2 Wye -Delta (Y-Δ)

 

 

Tare da firamare na Wye da sakandare na Delta, ana amfani da wannan tsarin sau da yawa a mataki{0}}asashen aikace-aikace inda na farko ke buƙatar haɗin tsaka-tsaki, ko kuma a mataki{1}} aikace-aikace na sama lokacin da ake juyawa na'urar wuta.

Aikace-aikace:Ana iya samun wannan a cikin babban -matakin rabo{1}}asashe yanayin tasfoma don ciyar da lodin injinan masana'antu ko a cikin da'irar fara injin don manyan motoci. A cikin aikace-aikacen farawa na mota, manyan squirrel - ana haɗa manyan motocin keji a cikin Wye don farawa (rage yawan ruwa zuwa kusan ɗaya - kashi uku na al'ada) sannan a canza zuwa Delta don gudu, wanda galibi ake kira "Wye-Delta ko Tauraro{{6}Delta Starter".

Amfani:

  • Wye na farko yana ba da tsaka-tsaki don ƙaddamar da ƙasa idan an so
  • Delta ta biyu tana ba da fa'idodi iri ɗaya kamar Delta{0}}ƙarfafa uku{1} fitarwa na lokaci, haƙurin kuskure tare da buɗewa{2}} damar delta, da keɓancewar jituwa sau uku
  • Yana da kyau ga aikace-aikacen da ke buƙatar juzu'in farawa mai tsayi ko tsaftataccen ƙarfin lokaci uku{0} ba tare da tsaka-tsaki ba

Iyakoki:Delta ta biyu ba za ta iya samar da kaya guda ɗaya{0} kai tsaye ba tare da ƙarin kayan aiki ba. Daidaita lodi akan tsaka tsaki na farko lokacin ciyar da sakandaren Delta na iya zama ƙalubale.

Yd±15°,Yd11

4.3 Delta -Delta (Δ-Δ)

 

 

Tare da na firamare da na sakandare biyu a Delta, wannan ƙa'idar tana ba da ƙaƙƙarfan aiki na lokaci uku{0} da ikon ci gaba da aiki a buɗe{1}}yanayin delta a rage ƙarfin aiki idan coil ɗaya ya gaza. Yana da kyau{3}}ya dace da ƙananan{4}}ƙarfin wutar lantarki, manyan{{5} aikace-aikace na yanzu inda manyan kaya uku- suka mamaye kuma buƙatar tsaka tsaki ba ta da yawa, kamar kayan injin masana'antu da kayan walda. Koyaya, baya bayar da haɗin kai ta kowane bangare kuma saboda haka ba zai iya yin aiki kai tsaye -Layin lokaci{9}}zuwa{10}} lodi.

Dd0

 

4.4 Wye -Wye (Y-Y)

 

 

Wye{0}Wye shine mafi kyawun tsarin tattalin arziki, yana ba da maki tsaka-tsaki a ɓangarorin biyu kuma babu canjin lokaci tsakanin ƙarfin firamare da na sakandare, wanda ke sauƙaƙa daidaita tafsiri masu yawa. Yana aiki da kyau don ma'auni na ma'auni da tsarin da ke buƙatar tsaka-tsaki na sama da ƙasa. Koyaya, Wye -Wye transformers sun fi saurin kamuwa da lamuran jituwa sai dai in ba a gama tsaka mai wuya na farko ba ko kuma an ƙara babbar iska ta Delta. Ana buƙatar daidaita nauyi a hankali don hana yin lodin tsaka tsaki daga nauyin nauyi mara nauyi ɗaya{5}}.

Yy0y6

YNyn0


 

 

 

5. Voltage da Dangantakar Yanzu

 

 

Ƙididdigar rabon juyi sun bambanta dangane da ƙayyadaddun tsari:

Delta -Wye (Δ-Y):Don mataki -saukarwa delta{1}}wye transformer tare da juyi juyi na N (na farko zuwa na biyu kowace nada), ƙarfin layin na biyu shineinfo-510-48. Akasin haka, lissafin ya haɗa da ainfo-36-44dalili saboda canji daga wutar lantarkin layin Delta zuwa layin Wye -zuwa{1}}tsarar wutar lantarki.

Wye{0}}Delta (Y-Δ):Ga na'urar wuta ta wye{0}}delta, ƙarfin wutar lantarki na layi na biyu yana da alaƙa da ƙarfin juzu'i na farko ta hanyar juyi, amma ƙari.info-36-44dangantaka tana aiki dangane da ko kuna sauka ko hawa sama.

Delta -Delta (Δ-Δ) da Wye{2}}Wye (Y-Y):Don daidaitawar haɗin kai{{0} iri ɗaya, canjin ƙarfin lantarki yana bin sauƙin juyi:info-571-43, tare da sikelin ƙarfin layi kai tsaye.

 

 


 

 

 

6. La'akari da ƙasa

 

 

Ƙarƙashin ƙasa shine mafi mahimmancin abu ɗaya mafi mahimmanci lokacin zaɓi tsakanin Delta da Wye.

Wye Grounding Zabuka:Lokacin da tsaka tsaki na Wye ya kasance, zai iya zama ko dai:

  • Ƙarƙashin ƙasa:Haɗa kai tsaye zuwa ƙasa (mafi yawanci ga ƙarfin lantarki da ke ƙasa da 600V). Wannan yana ba da mafi ƙanƙanta hanyar dawowar kuskuren impedance.
  • Ƙarfafa juriya:Tsakanin tsaka-tsaki da aka haɗa zuwa ƙasa ta hanyar resistor wanda ke iyakance laifin ƙasa zuwa ƙayyadaddun ƙima, yawanci 5-400 amperes. Wannan yana rage lalacewa yayin kurakurai yayin da har yanzu yana ba da hankali.
  • Rashin ƙasa ko mayar da martani:Tsakanin tsaka tsaki ya kasance keɓe daga ƙasa ko an haɗa shi ta hanyar reactor. Mafi qarancin gama gari a tsarin zama ko kasuwanci na zamani amma ana samunsa a wasu wuraren masana'antu ko manyan tsare-tsare masu tsayin daka-.

A cikin canza ƙirar ƙira, yanke shawarar ƙasa tsaka tsaki na haɗin Wye yana tasiri kai tsaye zaɓin yuwuwar taswira, masu kamawa, bushings, da sauran abubuwan haɗin gwiwa. Don tsarin Wye mai tushe, ana zaɓar abubuwan da aka haɗa bisa ga lokaci{1}}zuwa{2}} ƙarfin lantarki na ƙasa. Don tsarin da ba a yi ƙasa ba, dole ne a ƙididdige abubuwan haɗin gwiwa don ƙarfin lantarki na lokaci{4}}zuwa{5}}.

Kalubale na Ƙasar Delta:Ba tare da tsaka-tsaki ba, tsarin Delta ba zai iya zama ƙasa kamar tsarin Wye ba. Madadin haka:

  • Ƙaddamar da kusurwa:An haɗa madugu ɗaya da gangan zuwa ƙasa{0}hanyar mafi sauƙi amma yana haifar da babban ƙarfin wuta akan sauran matakan biyu dangane da ƙasa.
  • Cibiyar - ta danna ƙasa:A wasu sakandire na Delta, tsakiyar wurin iska ɗaya na iya zama a tsakiya{0}}matsawa da ƙasa don samar da iyakacin ƙarfin lokaci ɗaya{1}, kamar a cikin 240/120V uku-tsari na huɗu-wayoyin delta tsarin (wanda kuma aka sani da "high-ƙafa delta").
  • Taswirar ƙasa: A Zig{0}zagko Wye{0}}Za a iya ƙara tasfomar ƙasa don ƙirƙirar tsaka tsaki na wucin gadi don ƙaddamar da tsarin Delta mara tushe.

ZN

Muhimmin Bayanan Tsaro:Tsakanin tsaka tsaki na Wye yana samar da ƙananan hanyar rashin ƙarfi don magudanar ruwa na ƙasa, yana ba da damar da'ira da fis don share kurakurai cikin sauri. Wannan shine babban dalilin Wye na biyu ya fi son gine-ginen kasuwanci, wuraren kiwon lafiya, da sauran saitunan inda share kuskure da amincin ma'aikata ke da mahimmanci.

 

 


 

 

 

 

7. Canjin lokaci a Delta -Wye da Wye{2}}Delta Transformers

 

 

Muhimmin nuance na fasaha: a Delta -Wye da Wye{1}}Delta transformers, firamare na farko da na sakandare suna canzawa ta dabi'a da digiri 30. Wannan jujjuyawar lokaci tana faruwa ba a cikin iskar da kansu ba amma saboda yadda ake haɗa iska. Musamman, layin -zuwa{6}}layin wutar lantarki a gefen Wye ana canza shi da digiri 30 dangane da layin-zuwa-launi a gefen Delta.

Bayanan Agogo (Ƙungiyoyin Vector):Sau da yawa ana yin lakabi na haɗin kai ta hanyar alamar agogo don nuna canjin lokaci{0}misali, "Dy11" yana nufin matakin farko na Delta (D), Sakandare na Wye (y), tare da canjin lokaci wanda ya dace da sa'o'i 11 akan agogo, ko digiri 330 (daidai da digiri -30). "Yd1" yana nufin matakin sakandare ya zama na farko da digiri 30.

Me yasa Juyin Juya Hali ke da mahimmanci:Canjin mataki na digiri 30 ba batu ba ne a yawancin kayan aiki, amma yana zama mai mahimmanci lokacin da aka haɗa tafsiri. Idan aka haɗa tafsoshi biyu masu ƙungiyoyin vector daban-daban a layi daya, manyan igiyoyin zagayawa na iya haifar da su. Lokacin da ake haɗa taransfoma a layi daya, ƙungiyar vector dole ne ta dace ko a biya su da kyau. Misali, Dy11 wani lokaci ana iya daidaita shi da Yd1 idan an yi gyare-gyaren juyi na lokaci da ya dace.

Canjin mataki ba ya nana Delta{0}}Delta da Wye{1}}Haɗin Wye, wanda ke sauƙaƙa daidaitawa.

 


 

 

 

8. La'akari masu jituwa

 

 

Girgizar ƙasa ta Delta tana taka muhimmiyar rawa wajen sarrafa murdiya. Triplen masu jituwa (na uku, tara, na sha biyar, da sauransu) sun makale ta dabi'a kuma suna yawo a cikin iskar Delta maimakon yadawa zuwa layin wadata. Wannan siffa ta sa Delta{3}}Delta da Delta- Saitunan Wye suna da tasiri musamman wajen hana jujjuyawa daga lodi marasa kan layi daga shafar tsarin sama.

Wye-Wye transformers sun fi sauƙi ga wucewar hayaniyar jituwa tsakanin tushen da kaya. Don haka, lokacin da ake buƙatar haɗin Wye -Wye saboda wasu dalilai, ana ƙara manyan iskar Delta a wasu lokuta don baiwa masu jituwa sau uku hanya don yaɗawa.

 

 


 

 

 

 

9. Yadda Ake Zaba Daidaitaccen Kanfigareshan

 

 

Zaɓin mafi kyawun tsarin na'ura mai canzawa don aikace-aikacen da aka bayar ya haɗa da daidaita abubuwa da yawa:

9.1 Nau'in Load da Diversity

Tsarkakakkun nauyin nauyi guda uku{0} (manyan injina, kayan aikin masana'antu masu nauyi, masu walda) suna aiki da kyau tare da kowane tsari, amma Delta{1}}Delta yana ba da juriya mai ƙarfi da ikon ci gaba da aiki a buɗe{2}}delta bayan gazawa. Haɗaɗɗen lodi masu buƙatar duka biyu{4}}lokaci da guda -ikon lokaci ɗaya shine mafi kyawun aiki ta hanyar tsarin Delta{6}}Wye, wanda ke ba da tsaka tsaki mai tushe don rarraba lokaci ɗaya{7} yayin keɓance na farko daga rashin daidaituwa na biyu.

9.2 Abubuwan Buƙatun ƙasa

Idan tsaka tsaki mai tushe yana da mahimmanci don kariyar tsarin da share kuskure, sakanin Wye ya zama dole. Delta{1}Wye shine zaɓi na halitta don tsarin rarrabawa waɗanda ke buƙatar tsayayye, tsaka tsaki mai tushe a gefen lodi. Idan tsarin baya buƙatar tsaka tsaki kuma yana iya aiki ba tare da ƙasa ba ko tare da ƙasan kusurwa, Delta{3}}Delta na iya dacewa.

9.3 Abubuwan Jituwa

Tsarukan da ke da mahimmiyar jituwa{0}}masu samar da kaya (masu sarrafa mitoci, sauya kayan wuta, hasken LED,cibiyar bayanaikayan aiki) suna fa'ida daga jituwa - iyawar tarko na iskar Delta. Delta -Wye ko Delta- Ana ba da shawarar daidaitawar Delta a irin waɗannan lokuta.

9.4 Abubuwan Farawa don Manyan Motoci

Manya-manyan injuna waɗanda ke buƙatar raguwar farawar wutar lantarki na iya dacewa da shirin farawa na Wye{1}}Delta, inda aka fara motar a cikin Wye don iyakance inrush na yanzu sannan kuma a canza zuwa Delta don gudana.

9.5 Matsayin Tsarin Wutar Lantarki da Mataki{1}} Sama da Matakin -asa

Delta{0}}Ana amfani da Wye akai-akai don mataki{1}}asashe aikace-aikacen daga matsakaici{2}}ararrawar wutar lantarki zuwa ƙananan amfani da wutar lantarki. Wye{5}}Ana amfani da Delta sau da yawa don mataki{6}}asa, amma zaɓin da ke tsakanin su na iya zuwa kan ko ana buƙatar tsaka-tsaki a ɓangaren farko ko na sakandare.

9.6 Faɗawa na gaba da sakewa

Delta -Saitunan Delta suna ba da damar buɗewa{1}}majin delta{2} idan ɗaya tiransfoma a banki ya gaza, sauran biyun na iya ci gaba da isar da kusan kashi 58% na ƙididdigan matsayi uku{4}. Wannan na iya zama mahimmancin la'akari ga wurare masu mahimmanci.

 

 


 

 

 

10. Takaitawa

 

 

Haɗin Delta da Wye kowanne yana yin ayyuka daban-daban a cikin rarraba wutar lantarki guda uku{0}, kuma haɗin haɗin Delta ɗin su{1}Wye shine tsarin aikin masana'antu don rage ƙarfin watsa wutar lantarki zuwa matakan da ake amfani da su inda ake buƙatar kwanciyar hankali da gaurayawan lodi. Delta ta yi fice inda ƙwaƙƙwaran isar da wutar lantarki na lokaci uku{3} da haƙurin kuskure ke da mahimmanci, rufewa{4}}ƙirar madauki yana ba da kyakkyawan rabon kaya, kuma rashin tsaka tsaki ba iyaka ba ne. Wye ya yi fice inda ake buƙatar juzu'i, aiki mai tushe, da gauraye guda ɗaya{6}}sashi da nau'i uku{7}, yana ba da damar wutar lantarki biyu da tsayayyen tunani.

Babban taron gama gari tsakanin waɗannan duniyoyin biyu shine Delta{0}Wye transformer: Delta primary ta keɓe tsarin sama daga rashin daidaituwa da daidaituwa, yayin da sakandare ta Wye tana ba da tushe, tsayayyen tsaka-tsaki na gaske{1}} lodin duniya waɗanda ba su cika daidaitawa ba. Fahimtar lokacin da dalilin amfani da kowane saitin yana ba injiniyoyi damar haɓaka aiki, sarrafa nau'ikan kaya iri-iri yadda ya kamata, da sarrafa farashin aikin. Lokacin da ake shakka, duk - adadi na kusa don saukar da iko zuwa gauraye{5} wuraren amfani shine yawanci Delta{6}Wye, saboda yana ba da mafi kyawun ma'auni na iyawa, aminci, da aiki.

 


 

 

 

11. Kalma akan Tsaro

 

 

Koyaushe riko da duk lambobin lantarki masu dacewa da ka'idojin aminci lokacin aiki tare da taswira. Kar a taɓa ɗaukan tsarin yana da kuzari ba tare da ingantaccen gwaji ba. Matsakaicin girman kariyar wuce gona da iri da ƙasa suna da mahimmanci don aiki mai aminci. Idan ba ku da tabbas game da kowane fanni na zaɓi ko shigarwa, tuntuɓi injiniyan lantarki mai lasisi ko ƙwararren ƙwararren.

 

Aika Aikace-aikacen