BESS Transformer Design Guide From Harmonics to Grid Integration

 

1. Tsarin Tsarin Tsakanin Grid da BESS

 

A cikin tsarin ajiyar makamashin baturi (BESS), keɓancewar lantarki tsakanin grid da tsarin ajiyar makamashi yana da mahimmanci don kare inverter da tsarin batir daga wuce gona da iri da yanayin da ke haifar da rikicewar grid.

A lokaci guda, ana buƙatar jujjuyawar wutar lantarki don dacewa da matakan tsarin daban-daban, yawanci haɓakawa daga fitarwar inverter 400V zuwa 690V ko 480V BESS ƙarfin aiki, da ƙari zuwa matsakaici- matakan grid na wutar lantarki don haɗin haɗin mai amfani.

Ana samun wannan haɗin wutar lantarki ta hanyar BESS Transformer, wanda ke aiki a matsayin muhimmiyar hanyar haɗi tsakanin tsarin jujjuya wutar lantarki da grid mai amfani.

 

2. Ayyukan Tsarukan Ajiye Makamashin Batir

 

Baturi -Ajiye Makamashi (BESS) shine tsarin ajiyar makamashi mai tushe{1} wanda ke adana ingantaccen wutar lantarki da aka samar daga hanyoyin wuta daban-daban, gami da gawayi, nukiliya, iska, da hasken rana, ta hanyoyi da yawa. Yana iya adana wutar lantarki da yawa a lokacin mafi girman lokutan samar da makamashi mai sabuntawa (rana da iska) kuma a sake shi lokacin da ƙirƙira ta ragu ko amfani ya karu.

Haɗa BESS tare da sabbin hanyoyin samar da makamashi yana taimakawa inganta amincin grid da kwanciyar hankali, cikakken amfani da koren wutar lantarki. Bugu da ƙari, idan an daidaita ma'aunin da kyau kuma an haɗa shi da kyau{1}, wannan fasaha na iya daidaita farashin wutar lantarki kuma ta rage buƙatar sake gyara burbushin man fetur{2}.

 

  • Kololuwar aski & lodi mai biyo baya
  • Inganta ingancin wutar lantarki
  • Amincewa & tallafin madadin
  • Sabis na Grid & Tallafin Grid na Smart

 

typical Battery Energy Storage System

Tsarin Ajiye Makamashi na Batir (BESS) ya ƙunshi nau'ikan baturi da aka ajiye a cikin kwandon jigilar kaya mai ƙafa 20, wanda aka haɗa da inverter da transformer. Wannan tsarin yawanci ana haɗa shi da tsarin hasken rana wanda ke haifar da kai tsaye (DC). Ana adana wutar DC kai tsaye a cikin batura kuma a canza zuwa alternating current (AC) kamar yadda ake buƙata, sannan a ciyar da shi zuwa grid ta hanyar inverter da transformer.

 

3. Abin da ke Ma'anar Ƙirƙirar Mai Canjin BESS na Gaskiya

 

BESS tafofi na gaskiya ba taswirar rarrabawa ce da aka gyara ba.

Kayan lantarki ne na musamman wanda aka ƙera musamman don tsarin ajiyar makamashin baturi, inda hawan keke, masu jituwa, da kwararar wutar lantarki biyu sune yanayin aiki na yau da kullun. Yana aiki da dogaro a cikin tsarin wutar lantarki mai ƙarfi na tsarin ajiyar makamashin baturi, yana ci gaba da daidaitawa zuwa yanayin sauya kaya da yanayin motsi.

 

3.1 An Ƙirƙira don Cigaban Kewar Makamashi

 

BESS transformer yana aiki ƙarƙashin maimaita caji da sake zagayowar fitarwa, sau da yawa a rana. Wannan halin hawan keke yana haifar da yanayin zafi da na lantarki waɗanda ba su cikin aikace-aikacen rarraba na gargajiya.

Mahimman abubuwan ƙira sun haɗa da:

  • Ingantaccen tsarin sanyaya ONAN / ONAF don aiki na keke
  • Babban kayan rufin ajin thermal don tsayin juriya na thermal
  • Sarrafa zafi mai zafi{0}}hawan yanayin zafi a ƙarƙashin yanayin kaya mai ƙarfi
  • Tsayayyen aiki a ƙarƙashin sauyin kaya akai-akai

Wannan yana tabbatar da dorewar dogon{0} a cikin tsarin ajiyar makamashi inda ake tsammanin ci gaba da samar da makamashi.

 

3.2 Masu jituwa -Mai Haƙuri Zane don Inverter{2}}Tsarin Tsari

 

A cikin tsarin lantarki na BESS na zamani, tsarin jujjuya wutar lantarki (PCS) da inverters suna gabatar da gagarumin jujjuyawar jituwa da rashin yanayin lodawa na layi.{0}.

Don haka dole ne BESS transfomer da ya dace ya haɗa da:

  • K - ƙira mai ƙima (yawanci K-4 zuwa K-20 dangane da aikace-aikacen)
  • Rage ɓacin rai da ingantaccen ƙirar hanyar maganadisu
  • Inganta tsarin iska don rage asarar jituwa
  • Ƙarƙashin ƙarancin halin yanzu da ƙarin asara batacce

Waɗannan fasalulluka suna haɓaka kwanciyar hankali da amincin aiki a cikin jituwa{0}}wasu wurare masu wadatarwa irin na manyan sikelin BESS{1}.

 

3.3 Babban dv/dt Tsarin Insulation don Canjawar PCS

 

Ayyukan sauyawa da sauri a cikin tsarin PCS suna haifar da matsananciyar ƙarfin lantarki na dv/dt, wanda ke sanya ci gaba da matsa lamba akan tsarin rufin wuta.

Don tabbatar da dorewar dogon lokaci{0} dielectric, injin BESS na gaskiya yana buƙatar:

  • Babban rufin dv/dt yana jure iyawa
  • Sashe na fitarwa{0}tsarin rufin juriya
  • Ƙirar daidaitawar dielectric
  • Ingantattun jurewar wutar lantarki don yanayi na wucin gadi

Wannan dabarar ƙira tana kare na'urar watsawa daga maimaituwar matsananciyar wutar lantarki da aka haifar a cikin tsarin ajiyar makamashi.

 

3.4 Garkuwar Wutar Lantarki da Tsancewar Grid

 

Tsaro na lantarki da na lantarki yana da mahimmanci a cikin grid{0} aikace-aikacen BESS da aka haɗa, musamman inda ingancin wutar lantarki da kwanciyar hankali ke da mahimmanci.

Ayyukanta sun haɗa da:

  • Rage haɗin gwiwa mai ƙarfi tsakanin windings
  • Danne tsangwamar wutar lantarki na wucin gadi
  • Inganta aikin dacewa na lantarki (EMC).
  • Haɓaka kwanciyar hankali a cikin yanayin grid mai rauni

Wannan yana da mahimmanci musamman a cikin tsarin amfani - sikelin wutar lantarki na BESS inda yawancin inverters ke aiki a layi daya.

 

3.5 Ƙananan -Ƙarancin Ƙirar Ƙira don Babban -Aikin Ingantaccen aiki

 

Tunda makamashi a cikin tsarin BESS yana wucewa ta cikin na'ura mai canzawa yayin caji da zagayowar zagayowar, ko da ƙananan asara na iya tasiri ga ingantaccen tsarin gaba ɗaya.

 

Haɓaka ƙira na asali sun haɗa da:

Grain-oriented silicon steel

Siffar Zane ta Core

Amfanin Aiki

Amorphous karfe core

Ultra{0}}ƙananan hasara{1}

Silicon karfe -madaidaicin hatsi

Babban kaya yadda ya dace

Mataki - ginshiƙan gini

Rage amo da asarar maganadisu

Waɗannan haɓakawa kai tsaye suna ba da gudummawa kai tsaye zuwa mafi girman inganci na tafiya a cikin BESS.

 

 

3.6 Eco -Aboki da Wuta{2}}Tsarin Rufewa

 

Zane-zane na BESS na zamani yana ƙara ɗaukar fasaha mai aminci ga muhalli don biyan buƙatun aminci da dorewa.

Zaɓuɓɓukan rufi na gama gari sun haɗa da:

  • FR3 na halitta ester insulating ruwa
  • Babban man ma'adinai{0} don daidaitattun aikace-aikace
  • Babban fa'idodin ruwa na FR3:
  • Babban Wutar Wuta (~ 300 digiri) don inganta lafiyar wuta
  • Ingantattun yarda da muhalli don aikace-aikacen DER da BOS
  • Ingantattun halayen tsufa na thermal don tsawan rayuwar sabis

Wannan yana sa ya dace sosai don shigarwar taswirar BESS na waje a cikin abubuwan amfani{0}} ayyukan ajiyar makamashi.

FR3 natural ester insulating fluid

 

3.7 Tsarin - Abubuwan Bukatun Injiniya

Physical Energy Storage System

Dole ne mai canjin BESS ya haɗa tare da cikakken tsarin ajiyar makamashi:

• Matsala ta al'ada don lodin PCS
• Daidaitawa tare da saitunan inverter da yawa
• Ƙarfin nauyi mai yawa ba tare da lalata lalata ba
• Haɗin kai tare da tsarin sauyawa da tsarin kariya
• Taimakon aikin bidirectional

 

4. BESS Transformer Solutions ta SCOTECH

 

SCOTECH yana ba da ingantattun hanyoyin gyaran wuta don BESS, mai rufe tafsirin da aka ɗora tafsiri, ƙananan gidajen wutar lantarki, da masu wutar lantarki.

Kowane bayani an tsara shi musamman don buƙatun tsarin lantarki na BESS kamar:

• Bidirectional ikon kwarara
• Harmonic karkatarwa daga tsarin PCS
• Ci gaba da aikin hawan keke

Maimakon daidaitattun kayan aikin rarrabawa, SCOTECH yana mai da hankali kan aikace-aikace{0}}ƙayyadaddun injiniyan taswira don yanayin ajiyar makamashi na gaske.

 

4.1. Pad Dutsen Transformer don Aikace-aikacen BESS

 

Ana amfani da na'urorin da aka ɗora kumfa a ko'ina a cikin kwantena da tsarin BESS na kasuwanci, suna ba da ƙaƙƙarfan aiki mai inganci tsakanin PCS da grid.

Mahimman Bayani:

  • Ƙarfin Ƙarfi: 45 kVA - 10,000 kVA
  • Ƙarfin wutar lantarki: har zuwa 46 kV
  • Mitar: 50/60 Hz
  • Cooling: ONAN / ONAF / KNAN / LNAN
  • Shigarwa: Pad{0}} nau'in waje
  • Matsayi: IEEE / ANSI / CSA / NEMA / DOE
  • Abubuwan Zane na BESS:
  • Madaidaicin ciyarwar madauki / radial feed
  • Goyan bayan wutar lantarki na bidirectional
  • Matattu{0}}gaba/rayuwa{1}}tashoshin HV na gaba
  • Mai jituwa{0}} ƙira mai jurewa don lodin PCS
  • Surge da canza kariya ta wucin gadi
Pad Mounted Transformer For BESS Applications

4.2. Karamin Mai Canja Mai Sauƙi don Haɗin Grid na BESS

 

Kananan gidajen wutan lantarkiana amfani da su a matsakaici -matsakaicin tsarin haɗin gwiwar wutar lantarki BESS, inda daidaita wutar lantarki da grid ke da mahimmanci.

Small Substation Transformer For BESS Grid Integration

Maɓalli Na Farko:

  • Ƙimar wutar lantarki har zuwa 10 MVA
  • Matsayin ƙarfin lantarki har zuwa aji 161 kV
  • Mitar: 50/60 Hz
  • OLTC/NLTC zažužžukan musanyawa
  • Tsarin yarda da IEC / IEEE / CSA

 

BESS{0}}Abubuwan da suka dace:

  • Ƙarfin lodin masu jituwa (K{0}}abin da ya dace)
  • Babban gajeriyar ƙira mai ƙarfi{0}
  • Tsarin haɗin grid mai sassauƙa
  • Haɗin kai tare da tsarin sauyawa da tsarin kariya
  • Ya dace da babban yanayi da na'ura mai tsayi

 

4.3. Mai Canja Wuta don Mai Amfani{1}Scale BESS Systems

 

Ana amfani da na'urorin wutar lantarki a cikin manyan masana'antar ajiyar makamashi da grid{1}matakin BESS, inda inganci da aminci ke tasiri kai tsaye tsarin ROI.

Siffofin Zane na Core:

  • Mataki -cibin cinya don ƙarancin asara da ƙaramar amo
  • Masu gudanarwa na CTC don rage asarar tagulla
  • OLTC / NLTC tsarin sarrafa wutar lantarki
  • High thermal jimiri rufi tsarin
  • Eco{0}Zaɓuɓɓukan ruwa na abokantaka (FR3 akwai)

 

Amfanin Aikace-aikacen BESS:

  • An inganta shi don dogon aiki na ajiyar makamashi na zagayowar {{0}
  • Babban inganci a ƙarƙashin ci gaba da ɗaukar nauyin bidirectional
  • Inganta aikin kuzarin tafiya zagaye{0}
  • Ya dace da matsananciyar grid da yanayin muhalli
215Kwh-2MWh Container Battery Energy Storage System BESS

 

 

4.4. SCOTECH BESS Ƙarfin Injiniya & Haɗin kai

 

battery energy storage system Installation site

 

A cikin tsarin ajiyar makamashin baturi (BESS), mai sauya fasalin ba abu ne mai zaman kansa ba, amma maɓalli ne tsakanin PCS da grid.

Tsarin wutar lantarki na BESS na yau da kullun ya haɗa da na'urorin baturi, BMS, PCS, transformer, switchgear, da haɗin grid, inda makamashi ke gudana a dukkan kwatance yayin caji da fitarwa.

Don tabbatar da ingantaccen aiki a ƙarƙashin waɗannan sharuɗɗan, SCOTECH yana ƙirƙira masu canzawa bisa ainihin buƙatun tsarin maimakon daidaitattun jeri.

 

Mabuɗin iyawa sun haɗa da:
• Zane na al'ada bisa tsarin PCS/inverter
• Haɓakawa don bayanin martabar kaya da aikin hawan keke
• Tsarin jituwa{0}}tsari mai jurewa don tsarin inverter{1}}
• Daidaitawar impedance don daidaitawar tsarin tsarin
• Ƙarfin nauyi mai yawa ba tare da rage rayuwar rufi ba
• Yarda da ka'idojin IEEE / ANSI / CSA / IEC

 

Ana amfani da taransfoma na SCOTECH a ko'ina cikin amfani{0}}ma'auni, C&I, da sabuntar ayyukan BESS na haɗin gwiwar ajiya.

 

5. Me yasa Zane Mai Canjawa Yayi Tasirin ROI Kai tsaye

 

A cikin tsarin ajiyar makamashin baturi (BESS), sau da yawa ana raina na'urar wuta.

Amma yana shafar kai tsaye:

An tsara shi yadda ya kamata An tsara mara kyau
Ingantaccen tsarin mafi girma Mafi girman hasara na lantarki
Tsayayyen aikin keke na dogon lokaci{0} Ƙara yawan zafin rana
Ƙananan farashin O&M Rage aikin rayuwa
Mafi kyawun kuɗin shiga kowane MWh Yawaita zagi
Ingantattun ribar tsarin gaba ɗaya sama da shekaru 10-15 Ƙarƙashin fitarwar makamashi mai amfani

6. Kammalawa

 

Yayin da tsarin ajiyar makamashin baturi ke ci gaba da faɗaɗa, na'urar ta BESS ta zama muhimmin sashi don haɗa grid, ingantaccen tsarin, da amincin aiki. Ba kamar na'urorin wutar lantarki na gargajiya ba, dole ne ya yi tsayayya da kwararar wutar lantarki biyu, ci gaba da hawan keke, jituwa, da saurin inverter. Ƙirar da ta dace kai tsaye tana shafar aiki, kwanciyar hankali, da kuma dogon lokaci{2} ribar ayyukan BESS na zamani.