3635 kVA Mai Canjawa Tare da Rectifier-22 / 0.462 kV|Afirka ta Kudu 2022

3635 kVA Mai Canjawa Tare da Rectifier-22 / 0.462 kV|Afirka ta Kudu 2022

Ƙasa: Afirka ta Kudu 2022
Yawan aiki: 2× (3635/2562-2562) kVA
Wutar lantarki: 22/0.462kV
Feature: tare da OLTC
Aika Aikace-aikacen

 

 

3635 kVA transformer with rectifier

Daidaitaccen gyarawa, ingantaccen samar da wutar lantarki{0}}zaɓi na'ura mai daidaitawa don ƙarfafa makomar masana'antu!

 

01 Gabaɗaya

1.1 Fagen Aikin

3635 kVAmai gyara wutar lantarkiAn isar da shi zuwa Afirka ta Kudu a cikin 2022. Ƙididdigar ƙarfin wutar lantarki shine 3635 kVA tare da sanyaya OFAF. Babban ƙarfin lantarki shine 22kV, ƙarfin lantarki na biyu shine 0.267/0.462kV, sun kafa ƙungiyar vector na Yy0y6 ko Dy5y11. Rectifier Transformer kayan aikin gyara ne wanda ya ƙunshi tasfoma da masu gyara, don samun kuzarin kai tsaye daga wutar lantarki ta AC, ana amfani da su sosai a watsa wutar lantarki ta DC, gogayya ta lantarki, jujjuyawar ƙarfe, electroplating, electrolysis da sauran filayen. Ka'idar ta yi kama da na'ura mai ba da hanya tsakanin hanyoyin sadarwa, gefen asali na mai gyara na'ura yana haɗa da tsarin wutar lantarki na AC, wanda ake kira gefen cibiyar sadarwa; An haɗa gefen na biyu tare da mai gyara, wanda ake kira gefen bawul. Ka'idar tsarin na'urar gyaran fuska iri ɗaya ce da ta na'urar taransifoma ta yau da kullun.

Transformer tare da gyara yawanci ya ƙunshi manyan sassa biyu:

Bangaren Transformer: Ana amfani da shi don canza ƙarfin wutar lantarki na alternating current, yawanci yana jujjuya babban{0}}madaidaicin wutar lantarki zuwa ƙarami{1}}madaidaicin wutar lantarki don dacewa da buƙatun na'urar gyarawa. An tsara wannan ɓangaren bisa ga buƙatun aikace-aikacen kuma yana iya zama mai haɓakawa ko taswira{3} ƙasa.

Bangaren gyarawa: yawanci ya ƙunshi diodes, thyristors da sauran abubuwan gyara, na'urar ta canza canjin halin yanzu zuwa halin yanzu kai tsaye. Zane-zanen da'irar gyara zai shafi ingancin fitarwar DC, kamar jujjuyawar wutar lantarki da haɓakar fitarwa.

 

1.2 Ƙayyadaddun Fasaha

3635 kVA mai canzawa tare da nau'in ƙayyadaddun bayanai da takaddun bayanai

Isarwa zuwa
Afirka ta Kudu
Shekara
2024
Nau'in
mai gyara wutar lantarki
Daidaitawa
Saukewa: IEC60076
Ƙarfin Ƙarfi
3635 kVA
Yawanci
50HZ
Mataki
3
Nau'in Sanyi
OFAF
Babban Voltage
22 kv
Na biyu Voltage
0.462/0.433/0.39/0.346/0.303/0.26 kV
Abubuwan Iska
Copper
Matsala ta kusurwa
Yy0y6/Dy5y11
Impedance
6.5±10%
Matsa Canji
Farashin NLTC
Akan Rasa Load
114.4KW
Na'urorin haɗi
Daidaitaccen Kanfigareshan

 

1.3 Zane

3635 kVA mai canzawa tare da zane mai gyara da girman.

3635 KVA transformer with rectifier diagram 3635 KVA transformer with rectifier nameplate

 

 

02 Masana'antu

2.1 Kori

Babban abin da ke tattare da na’ura mai tauraro mai gyaran fuska yana daya daga cikin muhimman abubuwan da ke tattare da shi, wanda aka fi amfani da shi wajen gudanar da aikin maganadisu da inganta ingancin na’urar. Laminated core yawanci yana ƙunshe da zanen ƙarfe na siliki da yawa da aka jera a saman juna, waɗanda aka tsara kauri da kayan a hankali don rage asara da ɓarna.

A cikin tsarin masana'antu, waɗannan fakitin ƙarfe na silicon an toshe su a wani takamaiman hanya don samar da rufaffiyar da'irar maganadisu. Zane na laminated core iya yadda ya kamata rage makamashi hasãra da kuma ƙara da aikin na transformer.

Takardun ƙarfe na siliki yana da ƙarancin asarar hysteresis da ƙarfin injina, kuma yana iya jure yanayin zafi da girgizar da mai wuta ya haifar yayin aiki. Ta hanyar ingantacciyar hanya mai ma'ana, jigon tari zai iya sarrafa yanayin aiki na mai canzawa yadda ya kamata, samar da ingantaccen ƙarfin lantarki, da haɓaka ingantaccen aiki da amincin kayan aikin lantarki gabaɗaya.

3635 KVA transformer with rectifier iron core

 

2.2 Guda

3635 KVA transformer with rectifier continuous winding

Babban ƙarfin wutar lantarki mai ci gaba da jujjuyawa yawanci ya ƙunshi ƙarin juzu'i na wayoyi masu rufewa, waɗanda ke ci gaba da rauni akan tushen ƙarfe. Saboda jujjuyawar sa da yawa, yana iya jurewa mafi girman ƙarfin lantarki, don haka yana taka rawar ƙara ƙarfin lantarki a cikin injin gyara. Ƙirar wannan iska yawanci tana la'akari da ƙarfin rufewa a babban ƙarfin lantarki, ta yin amfani da manyan kayan kariya masu inganci don tabbatar da cewa ba za a sami raguwa ko matsala ba yayin aiki. A lokaci guda, tsari da ƙirar tsari na ci gaba da iska suna sa ya sami mafi kyawun daidaituwa na lantarki da rage tsangwama na lantarki.

Ƙarƙashin wutar lantarki -ƙara yana ɗaukar tsarin kek, wanda yawanci yana ƙunshe da ƴan juyawa kuma ya dace da buƙatun fitarwa na ƙarancin wutar lantarki. Wannan iskar ta sau da yawa tana ƙunshi nau'in faifai ko nau'in madugu nau'in zobe, waɗanda aka raba su da juna ta hanyar abin rufe fuska, sama da su. Zane na kek winding yana da kyawawan halaye na zubar da zafi, wanda zai iya rage yawan zafin da aka samar a cikin babban halin yanzu don tabbatar da kwanciyar hankali da amincin kayan aiki. Bugu da ƙari, tsarin kek ɗin yana taimakawa wajen rage shigar da ɗigogi da haɓakawa, inganta haɓakar wucewa ta yanzu, ta yadda mai canza canjin zai iya kula da kyakkyawar amsa mai ƙarfi lokacin da kaya ya canza.

 

2.3 Tanko

Tankin mai an yi shi ne da manyan faranti na ƙarfe masu ƙarfi waɗanda aka haɗa su tare, yana tabbatar da ƙarfin injina da maƙarƙashiya don jure matsi na ciki. Tankunan mai suna da na'urar adana mai a saman, wanda ke taimakawa daidaita haɓakawa da raguwar mai da kuma hana wuce gona da iri na ciki. Kasan tankin mai an sanye shi da magudanar ruwa don fitar da mai yayin kulawa. saman na iya samun abin numfashi ko iskar gas don daidaita matsi na ciki da na waje yayin hana shigar danshi.

transformer with rectifier high-strength steel oil tank

 

2.4 Taron Karshe

3635 KVA transformer with rectifier assembly
3635 KVA transformer with rectifier active part

 

 

03 Gwaji

1. Auna juriya na iska

2. Auna Girman Wutar Lantarki da Duba Matsugunin Mataki

3. Duba Insulation Core da Frame

4. Gwajin Karfin Wutar Lantarki

5. Gwajin Ƙarfin Wutar Lantarki

6. Auna A'a -Asarawar Load da Yanzu

7. Auna Gajerewar -Cikin Tsagewar Kewaye da Rasa Load

 

3635 KVA transformer with rectifier test

 

04 Shiryawa da jigilar kaya

3635 KVA transformer with rectifier packing

3635 KVA transformer with rectifier shipping

 

05 Yanar Gizo da Takaitawa

SCOTECHgyare-gyaren injiniyoyi an ƙera su don isar da ayyuka na musamman, amintacce, da inganci, waɗanda aka keɓance su don biyan buƙatun aikace-aikacen masana'antu na zamani. Tare da fasaha na ci gaba, ingantaccen gini, da daidaito mara misaltuwa, suna tabbatar da jujjuyawar wutar lantarki da dorewa{1}. Ko kuna ƙarfafa manyan masana'anta-, tallafawa matakai masu mahimmanci, ko tuƙi sabbin hanyoyin samar da makamashi, muna musamman masu canjisamar da kashin bayan nasarar ku. Zaɓi samfuranmu kuma ku sami cikakkiyar ma'auni na inganci, ƙirƙira, da amana. Tare, bari mu iko da nan gaba!

3635 KVA transformer with rectifier supplier

 

Hot Tags: transformer tare da rectifier, manufacturer, maroki, farashin, farashi