100 KVA Transformers A kan Wutar Wuta-13.8 / 0.347 KV|Kanada 2026

100 KVA Transformers A kan Wutar Wuta-13.8 / 0.347 KV|Kanada 2026

Kasar: Kanada 2026
Yawan aiki: 100 kVA
Wutar lantarki: 13.8/0.347 kV
Feature: tare da kama
Aika Aikace-aikacen

Jiangshan Scotech Electrical Co., Ltd yana ɗaya daga cikin masana'antun da suka fi dacewa kuma masu samar da na'urorin lantarki na kva 100 akan sandunan wutar lantarki{6}}13.8/0.347 kv|kanada 2026 in China. Da fatan za a ji kyauta don siyan kayayyaki masu inganci don siyarwa anan kuma ku sami zane-zane daga masana'anta. Tuntube mu don ƙarin bayani.

 

image001

Pole mounted transformer hadedde tare da kama walƙiya, tsayayya da hawan walƙiya da kyau.

 

 

01 Gabaɗaya

1.1 Bayanin Aikin

100 kVA single fase pole mounted transformer an isar da ita zuwa Kanada a cikin 2025. Ƙarfin wutar lantarkin shine kVA 100 tare da sanyaya ONAN. Babban ƙarfin lantarki shine 13.8 kV tare da ± 2 * 2.5% tapping range (NLTC), ƙananan ƙarfin lantarki shine 0.347 kV, sun kafa ƙungiyar vector na Ii6.

Taranfomar ta ƙirƙira kuma an gwada ta cikin cikakkiyar yarda da CSA C2.2{1}}06 - ƙa'idar Kanada don sandar sandar sandar sandar- ɗora tafsirin rarrabawa. An keɓance wannan na'ura mai ɗaukar hoto na musamman don Arewacin Amurka da cibiyoyin rarraba CSA masu dacewa.

Wuraren aikace-aikace na yau da kullun sun haɗa da:
• Layukan rarraba sama da karkara da na bayan gari da ke hidima ga wuraren zama da gonaki;
• Tsaya - samar da wutar lantarki shi kaɗai don ƙananan gine-ginen kasuwanci, tashoshi na famfo, da matsugunan sadarwa;
• Rassan sashe guda ɗaya- yana haɓaka tsarin lokaci guda uku{{1}.
Don jure wa barazanar wuce gona da iri akan layukan sama (haguwar walƙiya, sauye-sauye), ɓangaren farko na iya kasancewa da zaɓin sanye take da mai kamawa mai ƙarfi guda ɗaya, wanda zai iya ƙayyadadden haɓakar haɓaka mai shigowa da kuma kare tsarin rufin ciki. Haɗe da cikakken{1}} ma'aunin BIL na igiyar ruwa na 95kV (na farko) da ƙarfin ƙarfin lantarki da aka yi amfani da shi na 34 kV (na farko, 60 Hz), na'urar watsawa tana ba da ƙarfin aiki mai ƙarfi.

 

 

 

1.2 Ƙayyadaddun Fasaha

100 kVA sandar sandar da aka ɗora nau'in ƙayyadaddun bayanai da takaddun bayanai

Isarwa zuwa
Guyana
Shekara
2025
Nau'in
Pole mounted transformer
Daidaitawa
CSA C2.2-06
Ƙarfin Ƙarfi
100 kVA
Yawanci
60HZ
Mataki
1
Polarity
Ƙara
Nau'in Sanyi
ONAN
Babban Voltage
13.8 kV
Na biyu Voltage
0.347 kV
Abubuwan Iska
Copper
Matsala ta kusurwa
Ii6
Impedance
3.0%
Matsa Canji
±2*2.5%
Babu Asara Load
0.192 kW
Akan Rasa Load
1.52 kW
inganci
98.94%
Launi
haske launin toka, Lamba 70, Munsell bayanin kula 5BG7.0/0.4

 

1.3 Zane

100 kVA sandar sandar da aka ɗora zane da girman zane.

image003 image005

 

 

02 Masana'antu

2.1 Kori

image007

An ƙera ainihin asali ne daga babban ƙarfin ƙarfi, ƙarancin asarar hatsi mai daidaita siliki, an haɗa shi da daidaito don samar da rufaffiyar da'irar maganadisu. Wannan fasaha na lamination yana rage girman halin yanzu da asarar hysteresis, yana ba da gudummawa kai tsaye ga mafi kyawun injin na'urar ba ta da inganci. Aunawa babu asarar nauyi shine kawai 165 W a 100% ƙimar ƙarfin lantarki da 200 W a ƙimar ƙarfin lantarki 105%. Ƙwaƙwalwar jan ƙarfe mai ɗorewa yana ba da ingantaccen tushe mai tushe a ɓangarorin biyu, yana kawar da duk wani haɗari na yuwuwar iyo. A sakamakon haka, na'urar ta atomatik yana aiki a hankali, yana yin sanyi, kuma yana kula da inganci ko da a cikin yanayin nauyi mai sauƙi.

 

2.2 Guda

Dukansu babban ƙarfin lantarki da ƙananan ƙarfin wutar lantarki suna rauni gaba ɗaya daga jan ƙarfe na lantarki, suna ba da ingantaccen ƙarfin lantarki da ingantaccen ƙarfin injin akan gajerun runduna. Tsarin jujjuyawar mai da hankali, haɗe tare da hanyoyin mai da aka sanya dabara, yana haɓaka yaduwar mai na halitta (ONAN) don ingantaccen zubar da zafi. Iskar ta farko tana da ƙimar BIL na 95 kV, yayin da aka ƙididdige juzu'i na biyu a 30 kV, yana tabbatar da kariya mai ƙarfi daga walƙiya da jujjuyawa. An yi rikodin asarar nauyi a digiri 85 akan babban famfo a 1,459 W. Wannan ƙirar rauni na jan ƙarfe yana ba da tabbacin dogaro na dogon lokaci, ƙarancin juriya, da kyakkyawan aikin thermal.

image009

 

2.3 Tanko

image011

An ƙera tankin mai taswira ne daga ƙarfe mai ƙanƙanci mai inganci tare da cikakakken gini (hermetic) welded gini, yana hana duk wani ɗigowar mai ko ɗanshi. Ya yi nasarar wuce gwajin matsa lamba mai ƙarfi a 20 kPa na tsawon awanni 12, ba tare da yoyon da za a iya ganowa ba ko nakasar dindindin. An gama na waje da haske mai launin toka ANSI 70 (Munsell 5BG7.0/0.4) topcoat, samar da fice yanayi juriya da anti lalata kariya. Kayan aikin wutan lantarki sun haɗa da bawul ɗin taimako na nau'in zobe, mai sauya famfo, guraben ɗagawa mai nauyi, da haɗaɗɗen madaurin ƙasa. Kowane bangare na zane-zanen tanki yana mayar da hankali kan tsawon rayuwar sabis da ƙarancin kulawa a cikin yanayin waje.

 

2.4 Taron Karshe

An ƙera shi don hawan igiya mai dacewa, mai sauya fasalin ya zo cikakke tare da madaidaicin madaidaicin rataye. A gefe na farko, an shigar da ginshiƙai biyu na 15 kV: tashar H1 shine nau'in ƙulla hanyar 4 don haɗin layin sama mai sauƙi, yayin da tashar H2 ta kulle a cikin tanki, yana sauƙaƙe ƙasa ta waje. Gefen na biyu yana fasalta bushings nau'in G nau'in spade guda biyu tare da sanduna 3/{7}} da ramuka biyu a kowane ingarma, yana tabbatar da amintaccen haɗin gwiwa mara ƙarancin ƙarfi don ƙananan wutar lantarki. Matsayi na 5 a kashe mai sauya fam ɗin kewayawa yana ba da ±2 × 2.5% daidaitawar wutar lantarki (watau +5%, +2.5%, mara ƙima, -2.5%, -5%) don ɗaukar bambancin grid. A bakin karfe suna kwarkwata tare da abokin ciniki ta oda lambar da kuma samar da nuni ga bayyanannen traceability.

image013

 

2.5 Mai kamawa

image015

Don ingantacciyar kariya ta wuce gona da iri, ana iya samar da nau'in Juyin Juyin Halitta 12kV polymer mai ɗaukar nauyi mai ɗaukar nauyi (ɗaya a kowane lokaci), cikakke tare da keɓaɓɓen shingen hawa. Gidan polymer yana da nauyi, mai jurewa karaya, kuma yana ba da kyakkyawan aiki a cikin gurɓataccen yanayi ko matsanancin zafi. Mai kamawa yana amfani da fasaha na ƙarfe oxide varistor (MOV) don samar da sauri, daidaitaccen matsewar walƙiya da sauyawa masu wucewa. Ta hanyar tsotsewa da karkatar da kuzarin da ake samu, yana kare yadda ya kamata na keɓancewar tsarin na'urar taswira daga lalacewa. Ana ba da shawarar wannan mai kamawa na zaɓi don wuraren da ake yawan aikin walƙiya ko fallasa hanyoyin kan layi.

 

2.6 Valve Taimakon Matsi

Nau'in nau'in zobe na YSF jerin matsa lamba na bawul (PRD) an daidaita shi azaman kayan aiki na yau da kullun. An daidaita matsin lamba na sakinsa a 0.03 ± 0.01 MPa, kuma yana ba da damar kwararar 35 SCFM, yana ba da damar saurin fitar da iskar gas na ciki yayin yanayin kuskure. Karkashin aiki na yau da kullun, bawul ɗin ya kasance a rufe sosai ta hanyar na'urar da aka ɗora ruwan bazara; lokacin da matsa lamba ya tashi ba zato ba tsammani, yana buɗewa ta atomatik kuma yana sake saitawa da zarar an dawo da matakan tsaro. Zoben ja da hannu yana bawa ma'aikatan sabis damar yin iska mai sarrafawa yayin cika mai, kulawa, ko gwaji. Wannan PRD don haka yana aiki azaman na'urar aminci ta atomatik da kayan aiki mai dacewa, yana haɓaka amincin aiki sosai.

image017

 

 

03 Gwaji

Kowane tasfoma yana fuskantar cikakken gwajin gwaji na yau da kullun daidai da CSA C{0}}, tare da duk sakamakon da aka rubuta a cikin rahoton gwaji da aka sa hannu. Maɓallin ƙididdige ƙididdiga sun haɗa da juzu'in rabo na kawai -0.01% akan babban famfo da rashin ƙarfi na 3.21% (da kyau a cikin ± 7.5% haƙuri). Transformer ya sami inganci na 99.02%, ya wuce CSA C802.1 13 ƙaramar abin da ake buƙata na 98.94%. Gwajin wutar lantarki da aka yi amfani da su (na farko 34 kV, na sakandare 10 kV) da gwajin ƙarfin lantarki da aka jawo (150 Hz, 48 s) duk an kammala ba tare da lalacewa ba. Gwajin hatimin tanki a 20 kPa na sa'o'i 12 ya tabbatar da zubewar sifili, kuma binciken mai ya nuna ƙarfin dielectric na 65.1 kV tare da ɗanɗano abun ciki na 13.4 mg/kg kawai. Waɗannan sakamakon sun tabbatar da cikakken yarda da ingantaccen abin dogaro.

image019
image021

 

 

04 Shiryawa

4.1 Shiryawa

An cushe tafsirin a tsaye a cikin wani katako mai kauri ko karfe, wanda aka kera musamman don jure mugun aiki da jigilar nesa. Duk abubuwan da ke fitowa ko abubuwan da suka dace - bushings, bawul ɗin taimako na matsin lamba, ma'aunin mai, da mai kamawa - ana kiyaye su daban-daban tare da kumfa mai yanke kumfa na al'ada kuma, inda ya cancanta, an rufe su cikin kwalayen ciki. Wurin waje yana da alama a fili tare da lambar odar abokin ciniki da kuma bayanin samarwa don sauƙin ganewa a wurin da aka nufa. Marufin ya cika buƙatun kula da itace na ISPM-15 don jigilar kayayyaki na ƙasa da ƙasa, yana tabbatar da tsaftar kwastan. An haɗe cikakken jerin abubuwan tattarawa zuwa wajen akwatin.

 

4.2 Shipping

Na'urar taswira ta dace da kwantena na teku da jigilar kaya mai faffaɗa, tana ba da zaɓuɓɓukan dabaru masu sassauƙa. Cikakken binciken jigilar kaya yana tabbatar da girman gaba ɗaya, cikar taro, ƙarewar ƙasa, da alamun farantin suna. A lokacin lodawa, tsakiyar akwaku na nauyi yana daidaita a hankali tare da abin hawa ko akwati, kuma ana ajiye majajjawa a kusurwar Kasa da ko daidai da digiri 30 don tabbatar da rarraba nauyi. Babban madauri mai ƙarfi da ƙwanƙwasa amintacce suna lallasa kwalin don hana motsi cikin wucewa. Kowane jigilar kaya ya haɗa da rahoton gwaji na hukuma, jagorar koyarwar shigarwa, cikakken lissafin tattara kaya, da daftar kasuwanci. Ana iya shirya kulawar lodi na ɓangare na uku akan buƙatar ƙarin tsaro.

 

 

05 Taƙaitaccen

Wannan 100 kVA, 13.8 / 0.347 kV guda ɗaya sandar sandar sandar da aka ɗora taswira ta haɗu da ƙarancin ƙarancin silikon ƙarfe core, duk iska mai ƙarfi, ONAN sanyaya, da tankin ƙarfe mai laushi cikakke. An gina shi don saduwa da ƙa'idodin inganci na CSA C2.2 06 da CSA C802.1 13, tare da ma'aunin inganci na 99.02% - sama da garantin 98.94%. Ko kuna da alhakin haɓaka grid ɗin wutar lantarki ko ayyukan wutar lantarki a wurare masu nisa, ƙungiyar fasahar mu za ta ba da cikakken goyon bayan zagayowar - daga zaɓin kayan aiki zuwa haɗin grid.

image023

 

Hot Tags: 100 kva masu juyawa akan igiyoyin wuta-13.8 / 0.347 kv|kanada 2026, China 100 kva tasfoma a kan igiyoyin wuta-13.8/0.347 kv|Kanada 2026 masana'antun, masu kaya, masana'anta

Aika Aikace-aikacen